Página 1 - Thermostatic

1POWER SHOWERThese instructions are to be left with the userThermostaticTHERMOSTATICInstallation and User Guide

Página 2 - CONTENTS

10Gravity Fed system - The shower MUST be fed from a cold water cistern and hot water cylinder providing nominally equal pressure.INSTALLATION REQUIRE

Página 3 - INTRODUCTION

11INSTALLATIONGeneral1. Do not take risks with plumbing or electrical equipment.2. Do not install the shower unit in a position where it could becom

Página 4 - IMPORTANT SAFETY INFORMATION

12Plumbing1. A minimum storage capacity of cold water of 230 litres (50 gallons) is required to provide adequate showering time. Insufcient storage m

Página 5 - • If the case is damaged

13Warning! Do not x the shower unit to the wall until plumbing and electrical installations have been completed.1. Decide on a suitable

Página 6

143. Make sure that the end of the supply pipework is cut squarely and is free from burrs, which will damage the inlet manifold seals. Chamfer the e

Página 7 - PACK CONTENTS

157. Temporarily locate the shower unit.8. Position the shower unit on the wall and mark the three xing points. Note! Installers may wish to obtain

Página 8 - DIMENSIONS

1612. Fit the three rubber feet into the recesses in the rear of the case as shown. The feet will reduce the noise transmitted by the power shower th

Página 9 - SPECIFICATIONS

1714. Locate the shower unit on the inlet supplies and push the inlet manifold onto the pipework until resistance is felt. DO NOT FORCE! Note! PTFE

Página 10 - INSTALLATION REQUIREMENTS

1819. Ret the unit cover and secure with the three cover securing screws.20. Insert the ow control knob in the OFF position.21. Insert the

Página 11 - INSTALLATION

19COMMISSIONINGThe unit must not be run dry. Before proceeding any further with the installation the shower unit must be commissioned.1. Connect the

Página 12

2CONTENTSIntroduction ...3Patents ...

Página 13

20Maximum Temperature SettingIt may be necessary to adjust the maximum temperature for site conditions to make sure of safe showering from the unit. M

Página 14

21Caution! When resistance is felt DO NOT USE FORCE to turn the spindle any further as this is the maximum shower temperature obtainable with the avai

Página 15 - Fixing Points

22Inner Temperature Control KnobDisabling the Temperature Override ButtonThe temperature override button allows the user to override the preset maximu

Página 16

23Outer Flow Control KnobOPERATIONFor safety reasons this appliance is tted with an adjustable maximum temperature setting. This must be checked and

Página 17 - Gear Wheel

24Press the Override Button and turn the Inner Temperature Control Knob anticlockwise.Outer Flow Control KnobOff Position3. To override the preset ma

Página 18

25Fault Diagnosis - User MaintenanceThe appliance is fully performance tested after assembly. Providing it has been correctly installed and is operate

Página 19 - COMMISSIONING

26Fault Diagnosis - Installer MaintenanceThe Thermostatic Power Shower is one part of an entire plumbing system. The tting of a pump places additiona

Página 20

27Malfunction Cause RemedyThe maximum shower temperature is too cold.Hot water cylinder temperature less than 12 °C above the showering temperature. M

Página 21

28Warning! There are no user serviceable components beneath the cover of the appliance. Only a competent tradesperson should remove the cover.Before

Página 22

29SPARE PARTS147.67 Check Valve Pack453.01 Cartridge - Thermostatic453.03 Motor Pump Assembly - components identied ‘A’453.07 Inlet Manifold Asse

Página 23 - OPERATION

3The Mira Vigour Thermostatic Power Shower is an all-in-one power shower with an integral mains voltage pump and separate controls for ow and tempera

Página 24 - Outer Flow Control Knob

30ACCESSORIESGenuine Mira accessories can be purchased direct from Customers Services (our contact details can be found on the back cover of this guid

Página 26

32CUSTOMER SERVICE© Kohler Mira Limited, November 20101088849-W2-D (B85N)GuaranteeYour product has the benefit of our manufacturer’s guarante

Página 27

4IMPORTANT SAFETY INFORMATIONWarning!1. Read all of these instructions and retain this guide for later use.2. Products manufactured by us are sa

Página 28 - MAINTENANCE

521. DO NOT commission this appliance if water leaks from the unit.22. DO NOT operate this appliance if water leaks from this appliance.23. Only a

Página 29 - SPARE PARTS

6Caution!1. Read all of these instructions and retain this guide for later use.2. Make sure that this guide is left with the user. Pass on this guid

Página 30 - ACCESSORIES

7PACK CONTENTS 1 x Thermostatic Power Shower  4 x Case Inserts 1 x Flow Control Knob 1 x Temperature Control Knob 1 x Temperature Indicato

Página 31

8DIMENSIONSAll dimensions are nominal and in millimetres.31066282102820201308088

Página 32 - CUSTOMER SERVICE

9ElectricalPower supply - 230-240 V at 50 Hz, fused at 3 Amps, via a double pole fused switch (not supplied) with a minimum contact separation of 3 mm