1POWER SHOWERThese instructions are to be left with the userThermostaticTHERMOSTATICInstallation and User Guide
10Gravity Fed system - The shower MUST be fed from a cold water cistern and hot water cylinder providing nominally equal pressure.INSTALLATION REQUIRE
11INSTALLATIONGeneral1. Do not take risks with plumbing or electrical equipment.2. Do not install the shower unit in a position where it could becom
12Plumbing1. A minimum storage capacity of cold water of 230 litres (50 gallons) is required to provide adequate showering time. Insufcient storage m
13Warning! Do not x the shower unit to the wall until plumbing and electrical installations have been completed.1. Decide on a suitable
143. Make sure that the end of the supply pipework is cut squarely and is free from burrs, which will damage the inlet manifold seals. Chamfer the e
157. Temporarily locate the shower unit.8. Position the shower unit on the wall and mark the three xing points. Note! Installers may wish to obtain
1612. Fit the three rubber feet into the recesses in the rear of the case as shown. The feet will reduce the noise transmitted by the power shower th
1714. Locate the shower unit on the inlet supplies and push the inlet manifold onto the pipework until resistance is felt. DO NOT FORCE! Note! PTFE
1819. Ret the unit cover and secure with the three cover securing screws.20. Insert the ow control knob in the OFF position.21. Insert the
19COMMISSIONINGThe unit must not be run dry. Before proceeding any further with the installation the shower unit must be commissioned.1. Connect the
2CONTENTSIntroduction ...3Patents ...
20Maximum Temperature SettingIt may be necessary to adjust the maximum temperature for site conditions to make sure of safe showering from the unit. M
21Caution! When resistance is felt DO NOT USE FORCE to turn the spindle any further as this is the maximum shower temperature obtainable with the avai
22Inner Temperature Control KnobDisabling the Temperature Override ButtonThe temperature override button allows the user to override the preset maximu
23Outer Flow Control KnobOPERATIONFor safety reasons this appliance is tted with an adjustable maximum temperature setting. This must be checked and
24Press the Override Button and turn the Inner Temperature Control Knob anticlockwise.Outer Flow Control KnobOff Position3. To override the preset ma
25Fault Diagnosis - User MaintenanceThe appliance is fully performance tested after assembly. Providing it has been correctly installed and is operate
26Fault Diagnosis - Installer MaintenanceThe Thermostatic Power Shower is one part of an entire plumbing system. The tting of a pump places additiona
27Malfunction Cause RemedyThe maximum shower temperature is too cold.Hot water cylinder temperature less than 12 °C above the showering temperature. M
28Warning! There are no user serviceable components beneath the cover of the appliance. Only a competent tradesperson should remove the cover.Before
29SPARE PARTS147.67 Check Valve Pack453.01 Cartridge - Thermostatic453.03 Motor Pump Assembly - components identied ‘A’453.07 Inlet Manifold Asse
3The Mira Vigour Thermostatic Power Shower is an all-in-one power shower with an integral mains voltage pump and separate controls for ow and tempera
30ACCESSORIESGenuine Mira accessories can be purchased direct from Customers Services (our contact details can be found on the back cover of this guid
31NOTES
32CUSTOMER SERVICE© Kohler Mira Limited, November 20101088849-W2-D (B85N)GuaranteeYour product has the benefit of our manufacturer’s guarante
4IMPORTANT SAFETY INFORMATIONWarning!1. Read all of these instructions and retain this guide for later use.2. Products manufactured by us are sa
521. DO NOT commission this appliance if water leaks from the unit.22. DO NOT operate this appliance if water leaks from this appliance.23. Only a
6Caution!1. Read all of these instructions and retain this guide for later use.2. Make sure that this guide is left with the user. Pass on this guid
7PACK CONTENTS 1 x Thermostatic Power Shower 4 x Case Inserts 1 x Flow Control Knob 1 x Temperature Control Knob 1 x Temperature Indicato
8DIMENSIONSAll dimensions are nominal and in millimetres.31066282102820201308088
9ElectricalPower supply - 230-240 V at 50 Hz, fused at 3 Amps, via a double pole fused switch (not supplied) with a minimum contact separation of 3 mm
Comentários a estes Manuais