Mira Escape Guia do Utilizador

Consulte online ou descarregue Guia do Utilizador para Loiças sanitárias Mira Escape. Mira Escape User guide Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 32
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
1
These instructions are to be left with the user
Installation & User Guide
Mira Escape Thermostatic Electric Shower
Vista de página 0
1 2 3 4 5 6 ... 31 32

Resumo do Conteúdo

Página 1 - Installation & User Guide

1These instructions are to be left with the userInstallation & User GuideMira Escape Thermostatic Electric Shower

Página 2 - Contents

10Double-poleIsolating SwitchConsumer UnitInstallationInstallation of Mira EscapeWarning! Turn off the electrical and water supplies before proceeding

Página 3 - Introduction

11Three case inserts are supplied with the Mira Escape, so that they can be trimmed to suit the supplies entering the product. Before tting the cover

Página 4 - Important Safety Information

12Feed cable into Case. Fit Earth sleeve (not supplied) and strip insulation.Do not twist cable cores.Firmly connect the conductors. Do not exert stra

Página 5

13Cold Water Supply Pipe (Bottom Entry)Service TunnelFixing ScrewHoles For CoverRetaining ScrewsCase InsertElectrical Supply CableTerminal BlockInlet

Página 6 - Pack Contents Checklist

14CommissioningTurn control to full cold. Turn the water supply fully on.Check for water leaks. Set control to ‘I’. S w i t c h o n e le c t r

Página 7

15Turn control to full cold. The temperature will rise slightly.Set control to ‘II’.0 - 10 Secs12.11.10.The temperature will rise further.A d j u s

Página 8

16The warmer the shower, the lower the ow rate and vice versa.Heated water is produced by adjusting the ow of cold water passed through a heater tan

Página 9

17Water inlet pressure uctuations due to other draw offs (e.g. ushing toilet). Shower temperature will be controlled to within ± 2°C of the set temp

Página 10 - Installation

18Using your ShowerRead the section “Important Safety Information” rst.Note! At the end of every shower make sure that the shower head points into th

Página 11

19Fault DiagnosisThe trouble shooting information tabled below gives details on probable causes and remedies should difculties be encountered whilst

Página 12

2ContentsIntroduction ...3Patents and Design Registration ..

Página 13

20Symptom Power LightLow Flow LightHeater Setting I/II/IIIProbable Cause Possible RemedyL o w o r n o ow.ON ON ON ONON ONONON ON

Página 14 - Commissioning

21Symptom Power LightLow Flow LightHeater Setting I/II/IIIProbable Cause Possible RemedyWater will not turn off.ON ONOFF ONAny AnyInlet valve, sol

Página 15 - 0 - 5 Secs

22Make sure that the electrical supply is turned off at the mains and that the water supply is fully turned off.Remove the three screws, the

Página 16 - User Instructions

23FilterHold a wrench across the ats of the metal connector. Unscrew the filter using another wrench as shown. Clean or renew the Filter as neces

Página 17

24Spare PartsMira Escape405.58 Inlet Connector Assembly406.27 Inlet Filter (with ‘O’ seal tted)416.38 Clamp Bracket (Inlet)416.41 Thermal Switch4

Página 18

25405.58406.27416.38416.41416.48416.51872.01872.281563.5071563.539AAAAAAAAAA1563.6941563.534BB1563.5191563.5441563.5451563.5331563.5371563.538CCCCC156

Página 19 - Fault Diagnosis

26Dimensions90 mm79 mm207 mm340 mm348 mm

Página 20

27Wiring DiagramThermal CutoutDual DiscTank ConnectionLoadInlet ConnectorPressure/Power Selector SwitchSolenoid ValveLow Flow NeonPower On NeonSTART/S

Página 21

28Notes

Página 23

3IntroductionThank you for purchasing a quality Mira product. To enjoy the full potential of your new product, please take time to read this guide tho

Página 25

31Customer ServicesSpare PartsWe maintain an extensive stock of spares, and aim to have functional parts available for ten years from the date of nal

Página 26 - Dimensions

321060688-W2-C (1563) (J95G/H) © Kohler Mira Limited, April 2007Mira Showers Kohler Mira Ltd Cromwell Road, Cheltenham GL52 5EP.Mira is a registered

Página 27 - Wiring Diagram

4Important Safety InformationInstallation must be carried out in accordance with these instructions, and must be conducted by designated, qualied and

Página 28

52. Caution!2.1. Read all of these instructions and retain this guide for later use.2.2. The electrical installation must comply to “BS 7671 - Requ

Página 29

6Pack Contents ChecklistMira Escape 3 x Wall Plugs 3 x Fixing Screws 1 x Mira Escape 1 x Compression Nut 1 x Olive 3 x Case InsertsTick the appropriat

Página 30

7Specifications1. PlumbingMinimum maintained inlet pressure 70 kPa (0.7 bar).100 kPa (1.0 bar) recommended for satisfactory operation.Maximum static i

Página 31 - Customer Services

8Avoid layouts where the shower hose will be sharply kinked. This may reduce the life of the hose.A Soap Dish/Hose Retaining Ring is supplied to preve

Página 32 - Cheltenham GL52 5EP

92. ElectricalIn a domestic installation, the rating of the electricity supplier’s fuse and the consumer unit must be adequate for the additional dema