1These instructions are to be left with the userInstallation and User GuideELECTRIC SHOWERMIRA AZORA
10Double-pole Isolating SwitchConsumer UnitINSTALLATIONInstallation of Mira AzoraWarning! Turn off the electrical and water supplies before proceeding
11Before tting the Cover, make sure that the appropriate cutouts have been removed to suit the supply entering the product.Thoroughlyush
12Feed cable into Case. Fit Earth sleeve (not supplied) and then strip insulation.Do not twist cable cores.Firmly connect the conductors. Do
13Cold Water Supply Pipe (Bottom Entry)Fixing ScrewHoles For CoverRetaining ScrewsElectrical Supply CableTerminal BlockInlet Connector AssemblyHeater
14COMMISSIONINGTurn control to full cold. Turn the water supply fully on.Check for water leaks.Set control to ‘I’. Switch on electrical supply.P
15Turn control to full cold. The temperature will rise slightly.Set control to ‘II’.0 - 10 Secs12.11.10.The temperature will rise further.Adjust t
16The warmer the shower, the lower the ow rate and vice versa.Heated water is produced by adjusting the ow of cold water passed through a heater tan
17The shower's top priority is to keep the desired water temperature constant. Electric showers with thermostatic control are able to keep a stab
18Using your ShowerRead the section “Important Safety Information” rst.Note! At the end of every shower make sure that the shower head points into th
19Water inlet pressure uctuations due to other draw offs (e.g. ushing toilet). Shower temperature will be controlled to within ± 2°C of the set temp
2If you experience any difculty with the installation or operation of your new Electric Shower, please refer to ‘Fault Diagnosis’, before contacting
20FAULT DIAGNOSISThe trouble shooting information tabled below gives details on probable causes and remedies should difculties be encountered whilst
21Symptom Start/Stop LightHeater Setting I/II/IIIProbable Cause Possible RemedyLow or no ow.ON ON ON ONOFF ONONAny Any Any AnyAny
22Symptom Start/Stop LightHeater Setting I/II/IIIProbable Cause Possible RemedyWater will not turn off.ON ONAny AnyInlet valve, solenoid, or sta
23Make sure that the electrical supply is turned off at the mains and that the water supply is fully turned off.Remove the three screws and
24DIMENSIONS100 mm77 mm233 mm367 mm
25SPARE PARTS405.58 Inlet Connector Assembly406.27 Inlet Filter (with ‘O’ seal tted)416.38 Clamp Bracket (Inlet)416.41 Thermal Switch416.48 Latc
26405.58406.27416.38416.41416.48416.51872.01872.281563.5071563.539AAAAAAAAAA1563.5341563.5191634.0091634.1181634.1191634.1201634.1211634.1221634.12316
27BROWNBROWNBROWNBROWNREDREDREDBROWNBROWNGREENBLUEBLUEBLACKBLACKBLACKGREENWIRING DIAGRAMThermal Cutout DiscTank ConnectionLoadInlet ConnectorPressure/
281062243-W2-G (J95L)© Kohler Mira Limited, November 2010CUSTOMER SERVICEGuaranteeYour product has the benefit of our manufacturer’s guarantee
3INTRODUCTIONThank you for purchasing a quality Mira product. To enjoy the full potential of your new product, please take time to read this guide tho
4IMPORTANT SAFETY INFORMATIONInstallation must be carried out in accordance with these instructions, and must be conducted by designated, qualied and
5Caution!1. Read all of these instructions and retain this guide for later use.2. The electrical installation must comply to “BS 7671 - Requirements
6Mira AzoraPACK CONTENTS CHECKLISTTick the appropriate boxes to familiarise yourself with the part names and to conrm that the parts are included. 3
7SPECIFICATIONS1. Plumbing• Minimum maintained inlet pressure 70 kPa (0.7 bar).• 100 kPa (1.0 bar) recommended for satisfactory operation.• Maximum
8• Avoid layouts where the shower hose will be sharply kinked. This may reduce the life of the hose.• A Hose Retaining Ring is supplied to prevent t
92. Electrical• In a domestic installation, the rating of the electricity supplier’s fuse and the consumer unit must be adequate for the additional d