Página 1 - MIRA AZORA

1These instructions are to be left with the userInstallation and User GuideELECTRIC SHOWERMIRA AZORA

Página 2 - CONTENTS

10Double-pole Isolating SwitchConsumer UnitINSTALLATIONInstallation of Mira AzoraWarning! Turn off the electrical and water supplies before proceeding

Página 3 - GUARANTEE

11Before tting the Cover, make sure that the appropriate cutouts have been removed to suit the supply entering the product.Thoroughlyush

Página 4 - IMPORTANT SAFETY INFORMATION

12Feed cable into Case. Fit Earth sleeve (not supplied) and then strip insulation.Do not twist cable cores.Firmly connect the conductors. Do

Página 5 - Caution!

13Cold Water Supply Pipe (Bottom Entry)Fixing ScrewHoles For CoverRetaining ScrewsElectrical Supply CableTerminal BlockInlet Connector AssemblyHeater

Página 6 - PACK CONTENTS CHECKLIST

14COMMISSIONINGTurn control to full cold. Turn the water supply fully on.Check for water leaks.Set control to ‘I’. Switch on electrical supply.P

Página 7 - INSTALLATION REQUIREMENTS

15Turn control to full cold. The temperature will rise slightly.Set control to ‘II’.0 - 10 Secs12.11.10.The temperature will rise further.Adjust t

Página 8

16The warmer the shower, the lower the ow rate and vice versa.Heated water is produced by adjusting the ow of cold water passed through a heater tan

Página 9 - 2. Electrical

17The shower's top priority is to keep the desired water temperature constant. Electric showers with thermostatic control are able to keep a stab

Página 10 - INSTALLATION

18Using your ShowerRead the section “Important Safety Information” rst.Note! At the end of every shower make sure that the shower head points into th

Página 11

19Water inlet pressure uctuations due to other draw offs (e.g. ushing toilet). Shower temperature will be controlled to within ± 2°C of the set temp

Página 12

2If you experience any difculty with the installation or operation of your new Electric Shower, please refer to ‘Fault Diagnosis’, before contacting

Página 13

20FAULT DIAGNOSISThe trouble shooting information tabled below gives details on probable causes and remedies should difculties be encountered whilst

Página 14 - COMMISSIONING

21Symptom Start/Stop LightHeater Setting I/II/IIIProbable Cause Possible RemedyLow or no ow.ON ON ON ONOFF ONONAny Any Any AnyAny

Página 15 - 0 - 5 Secs

22Symptom Start/Stop LightHeater Setting I/II/IIIProbable Cause Possible RemedyWater will not turn off.ON ONAny AnyInlet valve, solenoid, or sta

Página 16 - USER INSTRUCTIONS

23Make sure that the electrical supply is turned off at the mains and that the water supply is fully turned off.Remove the three screws and

Página 17

24DIMENSIONS100 mm77 mm233 mm367 mm

Página 18 - Using your Shower

25SPARE PARTS405.58 Inlet Connector Assembly406.27 Inlet Filter (with ‘O’ seal tted)416.38 Clamp Bracket (Inlet)416.41 Thermal Switch416.48 Latc

Página 19

26405.58406.27416.38416.41416.48416.51872.01872.281563.5071563.539AAAAAAAAAA1563.5341563.5191634.0091634.1181634.1191634.1201634.1211634.1221634.12316

Página 20 - FAULT DIAGNOSIS

27BROWNBROWNBROWNBROWNREDREDREDBROWNBROWNGREENBLUEBLUEBLACKBLACKBLACKGREENWIRING DIAGRAMThermal Cutout DiscTank ConnectionLoadInlet ConnectorPressure/

Página 21

281062243-W2-G (J95L)© Kohler Mira Limited, November 2010CUSTOMER SERVICEGuaranteeYour product has the benefit of our manufacturer’s guarantee

Página 22 - MAINTENANCE

3INTRODUCTIONThank you for purchasing a quality Mira product. To enjoy the full potential of your new product, please take time to read this guide tho

Página 23 - Cover Retaining Screw

4IMPORTANT SAFETY INFORMATIONInstallation must be carried out in accordance with these instructions, and must be conducted by designated, qualied and

Página 24 - DIMENSIONS

5Caution!1. Read all of these instructions and retain this guide for later use.2. The electrical installation must comply to “BS 7671 - Requirements

Página 25 - SPARE PARTS

6Mira AzoraPACK CONTENTS CHECKLISTTick the appropriate boxes to familiarise yourself with the part names and to conrm that the parts are included. 3

Página 26

7SPECIFICATIONS1. Plumbing• Minimum maintained inlet pressure 70 kPa (0.7 bar).• 100 kPa (1.0 bar) recommended for satisfactory operation.• Maximum

Página 27 - WIRING DIAGRAM

8• Avoid layouts where the shower hose will be sharply kinked. This may reduce the life of the hose.• A Hose Retaining Ring is supplied to prevent t

Página 28

92. Electrical• In a domestic installation, the rating of the electricity supplier’s fuse and the consumer unit must be adequate for the additional d